Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 798
Filtrar
1.
J Med Syst ; 48(1): 46, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656727

RESUMO

BACKGROUND: Preterm neonates are extensively monitored to require strict oxygen target attainment for optimal outcomes. In daily practice, detailed oxygenation data are hardly used and crucial patterns may be missed due to the snapshot presentations and subjective observations. This study aimed to develop a web-based dashboard with both detailed and summarized oxygenation data in real-time and to test its feasibility to support clinical decision making. METHODS: Data from pulse oximeters and ventilators were synchronized and stored to enable real-time and retrospective trend visualizations in a web-based viewer. The dashboard was designed based on interviews with clinicians. A preliminary version was evaluated during daily clinical rounds. The routine evaluation of the respiratory condition of neonates (gestational age < 32 weeks) with respiratory support at the NICU was compared to an assessment with the assistance of the dashboard. RESULTS: The web-based dashboard included data on the oxygen saturation (SpO2), fraction of inspired oxygen (FiO2), SpO2/FiO2 ratio, and area < 80% and > 95% SpO2 curve during time intervals that could be varied. The distribution of SpO2 values was visualized as histograms. In 65% of the patient evaluations (n = 86) the level of hypoxia was assessed differently with the use of the dashboard. In 75% of the patients the dashboard was judged to provide added value for the clinicians in supporting clinical decisions. CONCLUSIONS: A web-based customized oxygenation dashboard for preterm neonates at the NICU was developed and found feasible during evaluation. More clear and objective information was found supportive for clinicians during the daily rounds in tailoring treatment strategies.


Assuntos
Recém-Nascido Prematuro , Internet , Oximetria , Melhoria de Qualidade , Humanos , Recém-Nascido , Melhoria de Qualidade/organização & administração , Oximetria/métodos , Saturação de Oxigênio , Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica/métodos
2.
Lasers Med Sci ; 39(1): 110, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649644

RESUMO

The sample comprised 44 volunteers who had undergone some surgical procedure and were equally divided into four groups. G1 started the therapy 24 h after the surgical procedure with the device off. G2 followed the same time pattern, 24 h, but with the device turned on. G3 and G4 started therapy three days after the surgical procedure; in G3, the device was turned off, and in G4, the device remained on during therapy; each session lasted 30 min, using 660 nm (red), energy 180 J. For all groups, the therapy started with daily use for seven days and followed the interval use of three times a week until completed 21 days. The revaluation was performed after 7 and 21 days. The results found show changes in HR at rest, systolic and diastolic BP, and in peripheral oxygen saturation, which showed a significant difference in the groups that used on-therapy (p < 0.05). In the MCGILL Scale evaluation, the mean total score showed a more accentuated drop in the groups that used ILIB, (p < 0.05). ILIB may have prevented a more significant evolution of firosis levels; however, no changes were observed in the evaluation of sleep and anxiety. The application of the ILIB in patients undergoing plastic surgery was supported in terms of hemodynamics and pain; in addition, starting the ILIB application 24 h after the procedure proved to be more advantageous.


Assuntos
Procedimentos de Cirurgia Plástica , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Técnica de Ilizarov/instrumentação , Hemodinâmica , Adulto Jovem , Saturação de Oxigênio , Cirurgia Plástica/métodos
3.
Biosensors (Basel) ; 14(3)2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38534239

RESUMO

Traditional methods for measuring blood oxygen use multiple wavelengths, which produce an intrinsic error due to ratiometric measurements. These methods assume that the absorption changes with the wavelength, but in fact the scattering changes as well and cannot be neglected. We found that if one measures in a specific angle around a cylindrical tissue, called the iso-pathlength (IPL) point, the reemitted light intensity is unaffected by the tissue's scattering. Therefore, the absorption can be isolated from the scattering, which allows the extraction of the subject's oxygen saturation. In this work, we designed an optical biosensor for reading the light intensity reemitted from the tissue, using a single light source and multiple photodetectors (PDs), with one of them in the IPL point's location. Using this bio-device, we developed a methodology to extract the arterial oxygen saturation using a single wavelength light source. We proved this method is not dependent on the light source and is applicable to different measurement locations on the body, with an error of 0.5%. Moreover, we tested thirty-eight males and females with the biosensor under normal conditions. Finally, we show the results of measuring subjects in a hypoxic chamber that simulates extreme conditions with low oxygen.


Assuntos
Técnicas Biossensoriais , Saturação de Oxigênio , Masculino , Feminino , Humanos , Oxigênio , Oximetria/métodos , Luz
4.
Crit Care ; 28(1): 78, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486211

RESUMO

BACKGROUND: Near-infrared spectroscopy regional cerebral oxygen saturation (rSO2) has gained interest as a raw parameter and as a basis for measuring cerebrovascular reactivity (CVR) due to its noninvasive nature and high spatial resolution. However, the prognostic utility of these parameters has not yet been determined. This study aimed to identify threshold values of rSO2 and rSO2-based CVR at which outcomes worsened following traumatic brain injury (TBI). METHODS: A retrospective multi-institutional cohort study was performed. The cohort included TBI patients treated in four adult intensive care units (ICU). The cerebral oxygen indices, COx (using rSO2 and cerebral perfusion pressure) as well as COx_a (using rSO2 and arterial blood pressure) were calculated for each patient. Grand mean thresholds along with exposure-based thresholds were determined utilizing sequential chi-squared analysis and univariate logistic regression, respectively. RESULTS: In the cohort of 129 patients, there was no identifiable threshold for raw rSO2 at which outcomes were found to worsen. For both COx and COx_a, an optimal grand mean threshold value of 0.2 was identified for both survival and favorable outcomes, while percent time above - 0.05 was uniformly found to have the best discriminative value. CONCLUSIONS: In this multi-institutional cohort study, raw rSO2was found to contain no significant prognostic information. However, rSO2-based indices of CVR, COx and COx_a, were found to have a uniform grand mean threshold of 0.2 and exposure-based threshold of - 0.05, above which clinical outcomes markedly worsened. This study lays the groundwork to transition to less invasive means of continuously measuring CVR.


Assuntos
Lesões Encefálicas Traumáticas , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Humanos , Estudos de Coortes , Prognóstico , Estudos Retrospectivos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Saturação de Oxigênio , Canadá , Lesões Encefálicas Traumáticas/diagnóstico por imagem
5.
BMC Pulm Med ; 24(1): 120, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448844

RESUMO

BACKGROUND: A significant reduction in regional cerebral oxygen saturation (rSO2) is commonly observed during one-lung ventilation (OLV), while positive end-expiratory pressure (PEEP) can improve oxygenation. We compared the effects of three different PEEP levels on rSO2, pulmonary oxygenation, and hemodynamics during OLV. METHODS: Forty-three elderly patients who underwent thoracoscopic lobectomy were randomly assigned to one of six PEEP combinations which used a crossover design of 3 levels of PEEP-0 cmH2O, 5 cmH2O, and 10 cmH2O. The primary endpoint was rSO2 in patients receiving OLV 20 min after adjusting the PEEP. The secondary outcomes included hemodynamic and respiratory variables. RESULTS: After exclusion, thirty-six patients (36.11% female; age range: 60-76 year) were assigned to six groups (n = 6 in each group). The rSO2 was highest at OLV(0) than at OLV(10) (difference, 2.889%; [95% CI, 0.573 to 5.204%]; p = 0.008). Arterial oxygen partial pressure (PaO2) was lowest at OLV(0) compared with OLV(5) (difference, -62.639 mmHg; [95% CI, -106.170 to -19.108 mmHg]; p = 0.005) or OLV(10) (difference, -73.389 mmHg; [95% CI, -117.852 to -28.925 mmHg]; p = 0.001), while peak airway pressure (Ppeak) was lower at OLV(0) (difference, -4.222 mmHg; [95% CI, -5.140 to -3.304 mmHg]; p < 0.001) and OLV(5) (difference, -3.139 mmHg; [95% CI, -4.110 to -2.167 mmHg]; p < 0.001) than at OLV(10). CONCLUSIONS: PEEP with 10 cmH2O makes rSO2 decrease compared with 0 cmH2O. Applying PEEP with 5 cmH2O during OLV in elderly patients can improve oxygenation and maintain high rSO2 levels, without significantly increasing peak airway pressure compared to not using PEEP. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2200060112 on 19 May 2022.


Assuntos
Ventilação Monopulmonar , Cirurgia Torácica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Saturação de Oxigênio , Respiração com Pressão Positiva , Troca Gasosa Pulmonar , Estudos Cross-Over
6.
Eur J Pediatr ; 183(5): 2455-2461, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38470520

RESUMO

High concentrations of oxygen are often needed to optimize oxygenation in infants with persistent pulmonary hypertension (PPHN), but this can also increase the risk of hyperoxemia. We determined the occurrence of hyperoxemia in infants treated for PPHN. Medical records of infants ≥ 34 + 0 weeks gestational age (GA) who received inhaled nitric oxide (iNO) were retrospectively reviewed for oxygenation parameters during iNO therapy. Oxygen was manually titrated to target arterial oxygen tension (PaO2) 10-13 kPa and peripheral oxygen saturation (SpO2) 92-98%. The main study outcomes were the incidence and duration of hyperoxemia and hypoxemia and the fraction of inspired oxygen (FiO2). A total of 181 infants were included. The median FiO2 was 0.43 (IQR 0.34-0.56) and the maximum FiO2 was 1.0 in 156/181 (86%) infants, resulting in at least one PaO2 > 13 kPa in 149/181 (82%) infants, of which 46/149 (31%) infants had minimal one PaO2 > 30 kPa. SpO2 was > 98% in 179/181 (99%) infants for 17.7% (8.2-35.6%) of the iNO time. PaO2 < 10 kPa occurred in 160/181 (88%) infants, of which 81/160 (51%) infants had minimal one PaO2 < 6.7 kPa. SpO2 was < 92% in 169/181 (93%) infants for 1.6% (0.5-4.3%) of the iNO time.    Conclusion: While treatment of PPHN is focused on preventing and reversing hypoxemia, hyperoxemia occurs inadvertently in most patients. What is Known: • High concentrations of oxygen are often needed to prevent hypoxemia-induced deterioration of PPHN, but this can also increase the risk of hyperoxemia. • Infants with persistent pulmonary hypertension may be particularly vulnerable to the toxic effects of oxygen, and hyperoxemia could further induce pulmonary vasoconstriction, potentially worsening the condition. What is New: • Hyperoxemia occurs in the majority of infants with PPHN during treatment with iNO. • Infants with PPHN spent a considerably longer period with saturations above the target range compared to saturations below the target range.


Assuntos
Hiperóxia , Óxido Nítrico , Síndrome da Persistência do Padrão de Circulação Fetal , Humanos , Recém-Nascido , Hiperóxia/etiologia , Óxido Nítrico/administração & dosagem , Estudos Retrospectivos , Síndrome da Persistência do Padrão de Circulação Fetal/terapia , Masculino , Feminino , Administração por Inalação , Oxigênio/sangue , Oxigênio/administração & dosagem , Saturação de Oxigênio , Oxigenoterapia/métodos , Hipóxia/etiologia , Hipóxia/terapia
7.
Science ; 383(6690): 1471-1478, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38547288

RESUMO

Consciousness is lost within seconds upon cessation of cerebral blood flow. The brain cannot store oxygen, and interruption of oxidative phosphorylation is fatal within minutes. Yet only rudimentary knowledge exists regarding cortical partial oxygen tension (Po2) dynamics under physiological conditions. Here we introduce Green enhanced Nano-lantern (GeNL), a genetically encoded bioluminescent oxygen indicator for Po2 imaging. In awake behaving mice, we uncover the existence of spontaneous, spatially defined "hypoxic pockets" and demonstrate their linkage to the abrogation of local capillary flow. Exercise reduced the burden of hypoxic pockets by 52% compared with rest. The study provides insight into cortical oxygen dynamics in awake behaving animals and concurrently establishes a tool to delineate the importance of oxygen tension in physiological processes and neurological diseases.


Assuntos
Córtex Cerebral , Circulação Cerebrovascular , Hipóxia Encefálica , Medições Luminescentes , Saturação de Oxigênio , Oxigênio , Animais , Camundongos , Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/metabolismo , Oxigênio/sangue , Oxigênio/metabolismo , Pressão Parcial , Hipóxia Encefálica/sangue , Hipóxia Encefálica/diagnóstico por imagem , Hipóxia Encefálica/metabolismo , Vasodilatação , Medições Luminescentes/métodos , Luciferases/genética , Luciferases/metabolismo , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Hipercapnia/sangue , Hipercapnia/diagnóstico por imagem , Hipercapnia/metabolismo
8.
Clin Lab ; 70(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38469764

RESUMO

BACKGROUND: Normal hemoglobin is a tetrameric structure, consisting of two alpha-globin chains and two nonalpha (beta, gamma, delta) chains. Hemoglobinopathies occur when the presence of gene mutations affect the molecular structure or expression of the globin chains. METHODS: We reported the case of a 9-year-old Chinese girl who presented with abnormal low oxygen saturation values on pulse oximetry and no oximetry results were obtained during blood gas analysis (BGA). RESULTS: High-performance liquid chromatography (HPLC) and capillary electrophoresis demonstrated that the presence of a low oxygen affinity hemoglobin variant, characterized as hemoglobin Titusville, was proven by gene sequencing. The patient's mother and aunt also carry the hemoglobin variant, representing the first Chinese family case reported. CONCLUSIONS: Hemoglobin Titusville is a rare genetic hemoglobin structural defect. early diagnosis can help patients and clinicians avoid unnecessary anxiety and costly or excessive clinical investigations.


Assuntos
Hemoglobinopatias , Hemoglobinas Anormais , Feminino , Humanos , Criança , Saturação de Oxigênio , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Oximetria , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise , Oxigênio , Gasometria
9.
Medicine (Baltimore) ; 103(10): e37454, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457564

RESUMO

BACKGROUND: Phenylephrine may cause a reduction in maternal cerebral tissue oxygen saturation (SctO2) during Caesarean birth to prevent spinal hypotension; however, the effect of norepinephrine has not been assessed. We hypothesized that norepinephrine was more effective than phenylephrine in maintaining SctO2 when preventing spinal hypotension during Caesarean birth. METHODS: We conducted a randomized, double-blind, controlled study. Sixty patients were randomly assigned to prophylactic norepinephrine or phenylephrine to maintain blood pressure during spinal anesthesia for Caesarean birth. SctO2, systolic blood pressure, and heart rate were recorded. The primary outcome was the incidence of a 10% reduction of intraoperative SctO2 from baseline or more during Caesarean birth. RESULTS: The norepinephrine group had a lower incidence of more than 10% reduction of intraoperative SctO2 from baseline than that of the phenylephrine group (13.3% vs 40.0%, P = .02). The change in SctO2 after 5 minutes of norepinephrine infusion was higher than that after phenylephrine infusion (-3.4 ±â€…4.7 vs -6.2 ±â€…5.6, P = .04). The change in SctO2 after 10 minutes of norepinephrine infusion was higher than that after phenylephrine infusion (-2.5 ±â€…4.4 vs -5.4 ±â€…4.6, P = .006). The norepinephrine group showed greater left- and right-SctO2 values than the phenylephrine group at 5 to 10 minutes. However, the change in systolic blood pressure was comparable between the 2 groups. CONCLUSION: Norepinephrine was more effective than phenylephrine in maintaining SctO2 when preventing spinal hypotension during Caesarean birth. However, the changes in clinical outcomes caused by differences in SctO2 between the 2 medications warrant further studies.


Assuntos
Anestesia Obstétrica , Raquianestesia , Hipotensão , Gravidez , Feminino , Humanos , Fenilefrina/uso terapêutico , Norepinefrina/uso terapêutico , Vasoconstritores/uso terapêutico , Saturação de Oxigênio , Resultado do Tratamento , Hipotensão/etiologia , Hipotensão/prevenção & controle , Hipotensão/tratamento farmacológico , Cesárea/efeitos adversos , Raquianestesia/efeitos adversos , Método Duplo-Cego
10.
Medicina (Kaunas) ; 60(2)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38399563

RESUMO

Background and Objectives: The COVID-19 outbreak has necessitated the prolonged use of N95 facemasks in addition to traditional surgical facemasks by healthcare workers. The aim of this study was to investigate the effect of wearing N95 facemasks in addition to surgical facemasks on peripheral oxygen saturation (SpO2) and heart rate (HR) among dental professionals during routine care. Materials and Methods: This prospective study compared SpO2 and HR between dental providers wearing N95 + surgical facemasks vs. wearing a surgical facemask only. SpO2 and HR were recorded using a portable pulse oximeter before wearing the facemask (T0); at 30 min (T1); at 1 h (T2); and at the end of clinical activity (T3). Inter-group and intra-group differences were assessed with independent t tests and repeated measures ANOVA, respectively. Results: A total of 88 participants (57 wearing N95 + surgical facemasks, and 31 wearing a surgical facemask only) completed the study. The two groups did not statistically differ in SpO2 at different timepoints nor showed any intra-group differences. The participants wearing N95 + surgical facemasks exhibited a statistically higher HR at T0 (p = 0.007), T2 (p = 0.010), and T3 (p = 0.014) compared to those wearing a surgical facemask only. A statistically significant decrease was observed in HR between T0 and T3 in those wearing N95 + surgical facemasks (p = 0.012). No intra-group differences were seen in HR over time in those wearing a surgical facemask only. Conclusions: The continuous use of an N95 in addition to a surgical facemask did not show any significant effects in SpO2 during routine care; however, the concurrent use of an N95 and a surgical facemask seemed to be accompanied by a decrease in HR, although the values remained within the normal range.


Assuntos
COVID-19 , Humanos , Máscaras , Estudos Prospectivos , Saturação de Oxigênio , Frequência Cardíaca , Surtos de Doenças
11.
Photodiagnosis Photodyn Ther ; 45: 104003, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38336148

RESUMO

Hyperspectral Imaging (HSI) seamlessly integrates imaging and spectroscopy, capturing both spatial and spectral data concurrently. With widespread applications in medical diagnostics, HSI serves as a noninvasive tool for gaining insights into tissue characteristics. The distinctive spectral profiles of biological tissues set HSI apart from traditional microscopy in enabling in vivo tissue analysis. Despite its potential, existing HSI techniques face challenges such as alignment issues, low light throughput, and tissue heating due to intense illumination. This study introduces an innovative HSI system featuring active sequential bandpass illumination seamlessly integrated into conventional optical instruments. The primary focus is on analyzing oxyhemoglobin and deoxyhemoglobin saturation in animal tissue samples using multivariate linear regression. This approach holds promise for enhancing noninvasive medical diagnostics. A key feature of the system, active bandpass illumination, effectively prevents tissue overheating, thereby bolstering its suitability for medical applications.


Assuntos
Imageamento Hiperespectral , Fotoquimioterapia , Animais , Saturação de Oxigênio , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Iluminação
12.
Br J Anaesth ; 132(5): 945-956, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38368234

RESUMO

BACKGROUND: Pulse oximetry-derived oxygen saturation (SpO2) is an estimate of true arterial oxygen saturation (SaO2). The aim of this review was to evaluate available evidence determining the effect of skin tone on the ability of pulse oximeters to accurately estimate SaO2. METHODS: Published literature was screened to identify clinical and non-clinical studies enrolling adults and children when SpO2 was compared with a paired co-oximetry SaO2 value. We searched literature databases from their inception to March 20, 2023. Risk of bias (RoB) was assessed using the QUADAS-2 tool. Certainty of assessment was evaluated using the GRADE tool. RESULTS: Forty-four studies were selected reporting on at least 222 644 participants (6121 of whom were children) and 733 722 paired SpO2-SaO2 measurements. Methodologies included laboratory studies, prospective clinical, and retrospective clinical studies. A high RoB was detected in 64% of studies and there was considerable heterogeneity in study design, data analysis, and reporting metrics. Only 11 (25%) studies measured skin tone in 2353 (1.1%) participants; the remainder reported participant ethnicity: 68 930 (31.0%) participants were of non-White ethnicity or had non-light skin tones. The majority of studies reported overestimation of SaO2 by pulse oximetry in participants with darker skin tones or from ethnicities assumed to have darker skin tones. Several studies reported no inaccuracy related to skin tone. Meta-analysis of the data was not possible. CONCLUSIONS: Pulse oximetry can overestimate true SaO2 in people with darker skin tones. The clinical relevance of this bias remains unclear, but its magnitude is likely to be greater when SaO2 is lower. SYSTEMATIC REVIEW PROTOCOL: International Prospective Register of Systematic Reviews (PROSPERO): CRD42023390723.


Assuntos
Saturação de Oxigênio , Pigmentação da Pele , Adulto , Criança , Humanos , Estudos Retrospectivos , Revisões Sistemáticas como Assunto , Oximetria/métodos , Oxigênio , Hipóxia
13.
Sci Data ; 11(1): 248, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413602

RESUMO

This report presents the Harespod dataset, an open dataset for high altitude hypoxia research, which includes respiration and SpO2 data. The dataset was collected from 15 college students aged 23-31 in a hypobaric oxygen chamber, during simulated altitude changes and induced hypoxia. Real-time physiological data, such as oxygen saturation waveforms, oxygen saturation, respiratory waveforms, heart rate, and pulse rate, were obtained at 100 Hz. Approximately 12 hours of valid data were collected from all participants. Researchers can easily identify the altitude corresponding to physiological signals based on their inherent patterns. Time markers were also recorded during altitude changes to facilitate realistic annotation of physiological signals and analysis of time-difference-of-arrival between various physiological signals for the same altitude change event. In high altitude scenarios, this dataset can be used to enhance the detection of human hypoxia states, predict respiratory waveforms, and develop related hardware devices. It will serve as a valuable and standardized resource for researchers in the field of high altitude hypoxia research, enabling comprehensive analysis and comparison.


Assuntos
Doença da Altitude , Saturação de Oxigênio , Humanos , Altitude , Hipóxia , Respiração , Adulto Jovem , Adulto
14.
Sensors (Basel) ; 24(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38339639

RESUMO

The quantification of comfort in binding parts, essential human-machine interfaces (HMI) for the functioning of rehabilitation robots, is necessary to reduce physical strain on the user despite great achievements in their structure and control. This study aims to investigate the physiological impacts of binding parts by measuring electrodermal activity (EDA) and tissue oxygen saturation (StO2). In Experiment 1, EDA was measured from 13 healthy subjects under three different pressure conditions (10, 20, and 30 kPa) for 1 min using a pneumatic cuff on the right thigh. In Experiment 2, EDA and StO2 were measured from 10 healthy subjects for 5 min. To analyze the correlation between EDA parameters and the decrease in StO2, a survey using the visual analog scale (VAS) was conducted to assess the level of discomfort at each pressure. The EDA signal was decomposed into phasic and tonic components, and the EDA parameters were extracted from these two components. RM ANOVA and a post hoc paired t-test were used to determine significant differences in parameters as the pressure increased. The results showed that EDA parameters and the decrease in StO2 significantly increased with the pressure increase. Among the extracted parameters, the decrease in StO2 and the mean SCL proved to be effective indicators. Such analysis outcomes would be highly beneficial for studies focusing on the comfort assessment of the binding parts of rehabilitation robots.


Assuntos
Resposta Galvânica da Pele , Saturação de Oxigênio , Humanos , Escala Visual Analógica , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Medição da Dor , Oxigênio/análise
15.
J Infect Public Health ; 17(4): 601-608, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38377633

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) is a respiratory illness that leads to severe acute respiratory syndrome and various cardiorespiratory complications, contributing to morbidity and mortality. Entropy analysis has demonstrated its ability to monitor physiological states and system dynamics during health and disease. The main objective of the study is to extract information about cardiorespiratory control by conducting a complexity analysis of OSV signals using scale-based entropy measures following a two-month timeframe after recovery. METHODS: This prospective study collected data from subjects meeting specific criteria, using a Beurer PO-80 pulse oximeter to measure oxygen saturation (SpO2) and pulse rate. Excluding individuals with a history of pulmonary/cardiovascular issues, the study analyzed 88 recordings from 44 subjects (26 men, 18 women, mean age 45.34 ± 14.40) during COVID-19 and two months post-recovery. Data preprocessing and scale-based entropy analysis were applied to assess OSV signals. RESULTS: The study found a significant difference in mean OSV during illness (95.08 ± 0.15) compared to post-recovery (95.59 ± 1.03), indicating reduced cardiorespiratory dynamism during COVID-19. Multiscale entropy analyses (MSE, MPE, MFE) confirmed lower entropy values during illness across all time scales, particularly at higher scales. Notably, the maximum distinction between illness and recovery phases was seen at specific time scales and similarity criteria for each entropy measure, showing statistically significant differences. CONCLUSIONS: The study demonstrates that the loss of complexity in OSV signals, quantified using scale-based entropy measures, has the potential to detect malfunctioning of cardiorespiratory control in COVID-19 patients. This finding suggests that OSV signals could serve as a valuable indicator for assessing the cardiorespiratory status of COVID-19 patients and monitoring their recovery progress.


Assuntos
COVID-19 , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Saturação de Oxigênio , Estudos Prospectivos
16.
Sci Rep ; 14(1): 4811, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413660

RESUMO

This study aimed to investigate the association between the level of tissue oxygen saturation (StO2) and quadriceps/skeletal muscle dysfunction, measured using the Medical Research Council (MRC) scale and ultrasonography, in critically ill patients. Thirty-four patients hospitalized at the Critical Care Medicine Center of Kindai University Hospital, between January 2022 and March 2023, were enrolled in this study. The StO2 of the quadriceps muscle was measured via near-infrared spectroscopy. Muscle atrophy was measured by the thickness, cross-sectional area (CSA), and echo intensity of the rectus femoris (RF). These values were evaluated every alternate day until 13 days after admission or until discharge, whichever occurred first. Muscle weakness was assessed using the sum score of the MRC scale (MRC-SS), with the patient sitting at bedside. The mean age of the patients was 67.3 ± 15.3 years, and 20 (59%) were men. Seven patients (21%) were admitted for trauma, and 27 (79%) were admitted for medical emergencies or others. The mean score for the MRC-SS was 51.0 ± 7.9 points. RF thickness and CSA significantly decreased after day 7 (p < 0.05). There were no significant changes in StO2 levels during hospitalization. However, there were positive correlations between the nadir StO2 during hospitalization and MRC-SS, and changes in RF thickness and CSA at discharge (r = 0.41, p = 0.03; r = 0.37, p = 0.03; and r = 0.35, p = 0.05, respectively). StO2 in the quadriceps muscle may be useful for predicting muscle atrophy and dysfunction in patients with critical illnesses.


Assuntos
Estado Terminal , Saturação de Oxigênio , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Músculo Esquelético/diagnóstico por imagem , Músculo Quadríceps/diagnóstico por imagem , Atrofia Muscular/patologia , Oxigênio
17.
Int Wound J ; 21(3): e14814, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38415898

RESUMO

Our objective was to evaluate normative data for near-infrared spectroscopy (NIRS) in 110 healthy volunteers by Fitzpatrick skin type (FST) and region of the foot. We obtained measurements of the dorsum and plantar foot using a commercially available device (SnapshotNIR, Kent Imaging, Calgary Canada). On the dorsum of the foot, people with FST6 had significantly lower oxygen saturation compared to FST1-5 (p < 0.001), lower oxyhaemoglobin compared to FST2-5 (p = 0.001), but there was no difference in deoxyhaemoglobin. No differences were found on the plantar foot. When comparing dorsal and plantar foot, there was higher oxyhaemoglobin (0.40 ± 0.09 vs. 0.51 ± 0.12, p < 0.001) and deoxyhaemoglobin (0.16 ± 0.05 vs. 0.21 ± 0.05, p < 0.001) on the plantar foot, but no differences in oxygen saturation (dorsal 70.7 ± 10.8, plantar 70.0 ± 9.5, p = 0.414). In 6.4% of feet, there were black areas, for which no NIRS measurements could be generated. All areas with no data were on the dorsal foot and only found in FST 5-6. People with FST6 had significantly larger areas with no data compared to FST 5 (22.2 cm2 ± 20.4 vs. 1.9 cm2 ± 0.90, p = 0.007). These findings should be considered when using NIRS technology. Skin pigmentation should be evaluated in future NIRS studies.


Assuntos
Saturação de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Voluntários Saudáveis , Oxiemoglobinas ,
18.
Rheumatol Int ; 44(4): 611-620, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340159

RESUMO

Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud's phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland-Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was - 3% (SD: ± 5), 0% (SD: ± 2), and 1% (SD: ± 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).


Assuntos
Saturação de Oxigênio , Escleroderma Sistêmico , Humanos , Oxigênio , Teste de Caminhada , Reprodutibilidade dos Testes , Escleroderma Sistêmico/diagnóstico
19.
BMJ Open Respir Res ; 11(1)2024 02 29.
Artigo em Inglês | MEDLINE | ID: mdl-38423953

RESUMO

BACKGROUND: The optimal target oxygen saturation (SpO2) range for hospital inpatients not at risk of hypercapnia is unknown. The objective of this study was to assess the impact on oxygen usage and National Early Warning Score 2 (NEWS2) of changing the standard SpO2 target range from 94-98% to 92-96%. METHODS: In a metropolitan UK hospital, a database of electronic bedside SpO2 measurements, oxygen prescriptions and NEWS2 records was reviewed. Logistic regression was used to compare the proportion of hypoxaemic SpO2 values (<90%) and NEWS2 records ≥5 in 2019, when the target SpO2 range was 94-98%; with 2022, when the target range was 92-96%. RESULTS: In 2019, 218 of 224 936 (0.10%) observations on room air and 162 of 11 328 (1.43%) on oxygen recorded an SpO2 <90%, and in 2022, 251 of 225 970 (0.11%) and 233 of 12 845 (1.81%), respectively (risk difference 0.04%, 95% CI 0.02% to 0.07%). NEWS2 ≥5 was observed in 3009 of 236 264 (1.27%) observations in 2019 and 4061 of 238 815 (1.70%) in 2022 (risk difference 0.43%, 0.36% to 0.50%; p<0.001). The proportion of patients using supplemental oxygen with hyperoxaemia (SpO2 100%) was 5.4% in 2019 and 3.9% in 2022 (OR 0.71, 0.63 to 0.81; p<0.001). DISCUSSION: The proportion of observations with SpO2 <90% or NEWS2 ≥5 was greater with the 92-96% range; however, absolute differences were very small and of doubtful clinical relevance, in contrast to hyperoxaemia for which the proportion was markedly less in 2022. These findings support proposals that the British Thoracic Society oxygen guidelines could recommend a lower target SpO2 range.


Assuntos
Hipóxia , Saturação de Oxigênio , Humanos , Estudos Retrospectivos , Hipóxia/etiologia , Oxigênio , Hospitais
20.
Aging Clin Exp Res ; 36(1): 46, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381262

RESUMO

BACKGROUND: Acute kidney injury (AKI) is a major postoperative consequence, affecting prognosis of older patients. Effective prediction or intervention to predict or prevent the incidence of AKI is currently unavailable. AIMS: Dynamic changes of renal tissue oxygen saturation (RSO2) during surgery process are understudied and we intended to explore the distinct trajectories and associations with postoperative AKI. METHODS: This was a secondary analysis including data for older patients who underwent open hepatectomy surgery with informed consent. Latent class mixed models (LCMM) method was conducted to generate trajectories of intraoperative renal tissue RSO2 through different time points. The primary outcome was postoperative 7-day AKI. The univariate and multivariate regression analysis were performed to identify the relationship between distinct trajectories of renal tissue RSO2 and the risk of AKI. Meanwhile, the prediction efficacy of renal tissue RSO2 at different time points was compared to find potential intervention timing. RESULTS: Postoperative AKI occurred in 14 (15.2%) of 92 patients. There are two distinct renal tissue RSO2 trajectories, with 44.6% generating "high-downwards" trajectory and 55.4% generating "consistently-high" trajectory. Patients with "high-downwards" trajectory had significantly higher risk of postoperative AKI than another group (Unadjusted OR [Odds Ratio] = 3.790, 95% CI [Confidence Interval]: 1.091-13.164, p = 0.036; Adjusted OR = 3.973, 95% CI 1.020-15.478, p = 0.047, respectively). Predictive performance was 71.4% sensitivity and 60.3% specificity for "high-downwards" trajectory of renal tissue RSO2 to identify AKI. Furthermore, the renal tissue RSO2 exhibited the lowest level and the best results in terms of the sensitivity during the hepatic occlusion period, may be considered as a "time of concern". CONCLUSIONS: Older patients undergoing hepatectomy may show high-downwards trajectory of renal tissue RSO2, indicating a higher risk of AKI, and the lowest level was identified during the hepatic occlusion period. These findings may help to provide potential candidates for future early recognition of deterioration of kidney function and guide interventions.


Assuntos
Injúria Renal Aguda , Saturação de Oxigênio , Humanos , Estudos Prospectivos , Injúria Renal Aguda/etiologia , Rim/cirurgia , Consentimento Livre e Esclarecido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...